Heat pump (4-ton)

Trane 4TWR4048G1000A · 3410 Silver Spur Trl, Cedar Park, TX 78613

9 photosGenerate EPA 608 report

Details

Make
Trane
Model
4TWR4048G1000A
Serial
16123ABCD
Installed
Jul 9, 2016
Status
Replacement recommended
Age
10 years old
Refrigerant
R-410A
Full charge
9.2 lb
Capacity
4 ton
Efficiency
13.4 SEER2

No warranty on file

Location: Back yard

Photos

Refrigerant and leak rate

Trailing 12-month leak rate

33.7%Over the threshold
0%Threshold 10%50%

3.1 lb added over 12 months against a 9.2 lb full charge

Below the charge size where the federal repair rule applies, but this unit is losing refrigerant every season.

Recommend replacement

Thresholds and applicability are pending verification against current EPA rules. See the assumptions register.

Trailing 12-month leak rate

Refrigerant log

Every addition and recovery on this appliance. Retained for at least three years.

Export audit record
DateActionlbCylinderTechnicianNotes
Aug 19, 2026Added0.9 lbCYL-410-026Marcus ReedThird top-off in 12 months. Replacement recommended to customer.
Mar 2, 2026Added1.2 lbCYL-410-021Sofía Ramírez
Mar 2, 2026Leak testSofía RamírezElectronic leak detector: slight hit at evaporator coil.
Oct 13, 2025Added1.0 lbCYL-410-017Marcus ReedLow on charge, no visible leak. Recommended dye test.

Service history

  • Sep 10, 2026J-2026-0421Low charge diagnosisScheduledHeat pump low on charge again. Leak search, discuss replacement (3 top-offs in 12 months).Sofía Ramírez
  • Aug 19, 2026J-2026-0331Low charge diagnosisCompletedLow charge, added 0.9 lb. Third top-off.Marcus Reed
  • Mar 2, 2026J-2026-0102Low charge diagnosisCompletedLeak test, slight hit at evaporator. Added 1.2 lb.Sofía Ramírez
  • Oct 13, 2025J-2025-1188Low charge diagnosisCompletedLow charge, added 1.0 lb.Marcus Reed